Process water treatment in clinics
A system for the production of demineralised water, which is used as process water in treatment, is a combination of several components. In order to optimise these work processes, the DGSV advises stricter limit values. Many hospital management teams and AEMP managers are already adapting their process water production to these new requirements. This has several advantages. In addition to legal certainty, this results in direct cost savings.
Damage to medical devices is minimised:
Limescale deposits, corrosion and silicate deposits, which are visible signs of poor process water quality in instruments and devices, are observed much less frequently. This helps to increase service life and reliability and reduce the need for expensive repairs or replacement purchases. In addition, the efficiency of sterilisation and cleaning processes is improved, which in turn reduces operating costs and increases the safety of patient care.
Filter products
Residual Hardness Measurement with Testomat 808 – Indicator Solution Type 301 for Stable Analysis Results Original liquid chemistry from Heyl for residual hardness monitoring in technical water analysis With a threshold of 0.1 °dH, this indicator solution provides a reliable and precise reading of residual hardness, ideal for processes requiring continuous water monitoring. The liquid formulation allows easy handling and a dependable chemical reaction directly in the measuring device. Heyl's original indicator solution is suitable for use with the Testomat 808 and F-BOB series. With a guaranteed minimum shelf life of 7 months after shipment from our warehouse, the solution remains accurate and ready for use throughout the entire period. Features of Indicator 302 At a defined residual hardness threshold of 0.1 °dH, the indicator solution reacts reliably, making it a stable choice for medium hardness ranges. The bottles can be used directly in the device. The indicator ensures consistent dosing and reliable results over many measurement cycles. Applications of the Indicator Solution Boiler feed water monitoring Process water Reverse osmosis systems and technical supply systems
Testomat 808 Indicator 301 – Precise Measurement Original indicator solution, reliable determination of residual hardness in water The Testomat 808 Indicator 301, 500 ml bottle from Heyl, is an original indicator for the exact measurement of residual hardness with a threshold of 0.1 °dH. Suitable for the Testomat 808 and Testomat F-BOB devices. The Indicator 301 is reliable for monitoring residual hardness. It allows safe process control with minimal maintenance effort. Highly Precise Residual Hardness Determination The Testomat 808 Indicator 301 from Heyl is a specially developed original indicator for highly precise determination of residual hardness in water treatment systems. It is precisely calibrated to the measurement methodology of the Testomat 808 and Testomat F-BOB and ensures reliable detection of residual hardness up to a threshold of 0.1 °dH. Using the original Heyl indicator guarantees consistent measurement quality, as reaction behavior, color change, and stability are optimized for the device parameters. Only by using the original Testomat 808 Indicator can proper device functionality be ensured and the corresponding device warranty maintained. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
The Testomat 808 Indicator 302 for measuring residual hardness in water with the Testomat 808. Supplied in practical 2 x 100 ml bottles for stable and reliable results. For 100 ml bottles, the conversion kit (Item No. 37580) is required to use the indicators correctly. Testomat 808 Indicator 302 – Reliable Liquid Indicator for Medium Residual Hardness Fast and accurate residual hardness measurement in water The Testomat 808 Indicator 302 solution is specially developed for precise residual hardness measurement in the medium range. With a threshold of 0.2 °dH, it provides clear measurement results and enables reliable monitoring of process water and boiler feed water. Applications of Indicator 302 Thanks to its precise reaction at a medium residual hardness of 0.2 °dH, this indicator solution delivers consistent results. It is suitable for continuous use in industrial water treatment processes and ensures reliable measurement outcomes. Diverse Applications for the Testomat 808 Indicator 302 Process water Boiler feed water Reverse osmosis Technical water systems Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Testomat® 808 Indicator 302 500 ml Residual hardness threshold: 0.2 °dH for Testomat® 808 The Testomat 808 Indicator 302, 500 ml bottle, is designed for threshold monitoring of residual hardness at 0.2 °dH in water samples through color change. Indicator 302 enables precise measurement of residual hardness. It is optimized for the Testomat 808 and F-BOB to detect limescale deposits early. Precise Residual Hardness Monitoring at 0.2 °dH The Testomat® 808 Indicator 302 is a specially calibrated original indicator for reliable threshold monitoring of residual hardness in water samples at 0.2 °dH. The indicator solution is specifically designed for use with the Testomat® 808 and Testomat® F-BOB, enabling precise water hardness measurement through a clearly defined color change. Even the smallest deviations can be detected early, effectively preventing limescale deposits in downstream systems. Manufacturer Warranty and Original Indicators Full operational reliability and warranty claims for Testomat® devices can only be guaranteed when using original indicators. Using the original Indicator 302 ensures that measurement accuracy, device protection, and long-term reliability meet the manufacturer’s specifications. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Testomat 808 Indicator 303 – Precise Residual Hardness Measurement Original indicator solution for determining residual hardness The Testomat 808 Indicator 303, 500 ml bottle from Heyl, is an original indicator solution for measuring residual hardness through color change with the Testomat 808 and Testomat F-BOB. It provides clear results at a threshold of 0.1 °dH. Indicator 303 is designed for residual hardness monitoring. With minimal maintenance, it enables safe process control. Highly Precise Residual Hardness Monitoring The Testomat 808 Indicator 303 from Heyl is a specially developed original indicator solution for precise measurement of residual hardness in water samples through a clearly defined color change. It is optimally calibrated for use with the Testomat 808 and Testomat F-BOB and delivers reliable measurement results at a threshold of 0.1 °dH. Thanks to its exact adaptation to the measurement methodology of the devices, it ensures high measurement accuracy and reproducibility. Deviations can be detected early, effectively preventing limescale formation. Manufacturer Warranty and Original Indicators The manufacturer’s warranty for Testomat® devices can only be guaranteed when using Heyl original indicators. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: I Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
High-quality original indicator solution from Heyl for determining residual hardness in water with the Testomat 808 and F-BOB. Supplied as a 2 x 100 ml set for robust measurements. For 100 ml bottles, the conversion kit (Item No. 37580) is required to use the indicators correctly. Liquid Indicator 303 for Residual Hardness Monitoring with Testomat 808 Efficient residual hardness analysis with a clearly defined reaction The Testomat 808 Indicator 303 solution is specially designed for monitoring residual hardness in the medium measurement range and provides a defined reaction at a threshold of 0.3 °dH. Due to its reliable chemical reaction, this indicator is particularly suitable for industrial water monitoring where consistent and reproducible results are required. Practical Use of Indicator 303 The indicator is calibrated for the medium range of residual hardness measurement and delivers stable signals even from small bottles. Where a threshold of 0.3 °dH is critical, it supports monitoring of residual hardness in water processes. Diverse Applications of the Indicator Technical water supply Boiler and process water monitoring Reverse osmosis checks Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Liquid original indicator solution from Heyl for measuring residual hardness in water with the Testomat 808 and F-BOB device series. Supplied in a practical 2 x 100 ml set with a threshold of 0.5 °dH. For 100 ml bottles, the conversion kit (Item No. 37580) is required to use the indicators correctly. Testomat 808 Indicator 305 – Reliable Residual Hardness Testing at 0.5 °dH High-quality solution for precise residual hardness measurement in water processes This indicator reacts clearly and reliably at a defined threshold of 0.5 °dH in the 808 and F-BOB devices. This allows safe decisions regarding water quality. The solution ensures consistent reaction and facilitates easy handling. Why is this indicator particularly suitable? With its clear reaction threshold of 0.5 °dH, it offers a good balance between sensitivity and robustness. The formulation is optimized for reliable use in online water analysis systems for industrial applications. Typical Applications of Indicator 305 Boiler feed water monitoring Process water analysis Technical water treatment systems Frequently asked questions How long does the indicator/reagent keep? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators - Consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143). Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
The Testomat 808 Indicator 305, 500 ml bottle, is an original indicator solution for measuring residual hardness with a threshold of 0.5 °dH. The indicator is specially designed for Testomat 808 and Testomat F-BOB devices, providing precise and reliable measurement results. Benefits of the Original Testomat 808 Indicator 305 from Heyl The Testomat 808 Indicator 305 is optimally matched to the requirements of Testomat 808 and Testomat F-BOB devices and ensures reliable results during continuous operation. Your Advantages When Using Original Heyl Indicators at a Glance Maximum Measurement Accuracy: Precisely defined composition for reproducible and accurate residual hardness measurements. Perfect Device Compatibility: 100 % matched to Testomat 808 and Testomat F-BOB – no calibration issues or incorrect measurements. Reliable Process Monitoring: Ideal for continuous monitoring of residual hardness. System Protection: Early and reliable detection of limit value exceedances protects downstream processes and components. Warranty and Safety Through Original Heyl Quality Using the original Testomat 808 Indicator 305 ensures that the manufacturer-specified measurement accuracy, functional safety, and device lifespan are fully maintained. Using original indicators is a prerequisite for: proper operation of Testomat measuring devices maintaining warranty and guarantee claims compliant and reliable process control With the original indicator, you invest in measurement reliability, process stability, and long-term operational safety – without compromise. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Original Testomat 808 Indicator 310 from Heyl for Residual Hardness Monitoring Residual hardness threshold: 1 °dH for Testomat 808 and F-BOB The Testomat 808 Indicator 310, 500 ml bottle, measures the residual hardness in water as a threshold monitor with color change for the Testomat 808 and F-BOB. The threshold is set at 1 °dH. The Indicator 310 enables reliable threshold measurement of residual hardness through a color reaction. Benefits of the Original Testomat 808 Indicator 310 The Testomat 808 Indicator 310 is the original indicator solution from Heyl for monitoring residual hardness in water with a threshold of 1 °dH. Its clearly defined color change ensures safe and easily readable measurement results on the Testomat 808 and F-BOB devices. Your Advantages When Using Heyl Original Indicators for Testomat 808 at a Glance Reliable Threshold Measurement: Clear indication via green or red signal for safe detection of residual hardness exceeding 1 °dH. Optimized for the Measuring Device: Specifically designed for Testomat 808 and Testomat F-BOB – ensures trouble-free operation and precise results. High Process Reliability: Ideal for continuous monitoring of residual hardness in water-carrying processes. Consistent Indicator Quality: Ensures reproducible results throughout the entire usage period. Warranty and Operational Safety with Original Indicator 310 for Testomat 808 from Heyl Using the original Testomat 808 Indicator 310 is crucial for reliable measurement function and proper operation of the Testomat devices. Using original indicators ensures: compliance with manufacturer specifications full measurement accuracy and operational reliability retention of warranty and guarantee claims long-term protection for downstream systems With the original Testomat 808 Indicator 310, you rely on dependable threshold monitoring, stable processes, and maximum operational safety. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Original Heyl indicator solution in a double pack for determining the residual hardness in water with the Testomat 808 and F-BOB limit value measuring devices. The Testomat 808 310 indicator reacts at a limit value of 1 °dH. Residual hardness indicator 310 – colour-changing liquid solution for Testomat 808 Indicator solution for reliable indication of 1 °dH residual hardness The Testomat 808 Indicator 310 solution has been specially designed for monitoring higher residual hardness ranges in water. With a clearly defined measurement limit value of 0.1 °dH, the indicator produces clear colour changes in the Testomats, which provide rapid feedback on the condition of the water. Easy to use and clear measurement signals This indicator provides a clear colour reaction, which is particularly helpful when water quality checks are required in medium to higher hardness ranges. It is suitable for regular use in process and system monitoring and facilitates interpretation through clear colour signals. Individual areas of application for the Testomat 808 Indicator 310 from Heyl Industrial water monitoring Process water Supply systems
Original Testomat Indicator 320 solution for measuring increased residual hardness in water for use in the Testomat 808 and F-BOB limit value measuring devices. Available in a practical 2x100ml pack. Indicator 320 for increased residual hardness values in the Testomat 808 Reliable analysis solution for residual hardness up to 2 °dH In combination with the indicator solution and the Testomats, it supports the continuous monitoring of water quality parameters. This indicator is particularly suitable where higher residual hardness ranges are relevant and stable, reliable limit value displays are required. Its liquid form allows for easy application directly in the measuring device. Advantages for monitoring higher hardness ranges The 320 indicator is specially designed for residual hardness up to 2 °dH. This makes it ideal for applications in technical water systems where medium to higher hardness ranges must be monitored regularly and reliable measurement results are crucial. What are the possible areas of application? Monitoring residual hardness in reverse osmosis systems Boiler feed water Technical water supply Process water
Original indicator solution in a 500 ml bottle for measuring residual hardness in water with the Testomat 808 or F-BOB, designed for a limit value of 2 °dH. 500 ml indicator solution 320 from Heyl – residual hardness monitoring up to 2°dH Reliable liquid solution for detecting increased residual hardness Setting to a limit value of 2 °dH enables the targeted detection and monitoring of medium to higher hardness groups, which is particularly important for process water and feed water analyses. Efficiently support the measurement of increased hardness ranges – with the Testomat 808 Indicator 320 The indicator has been specially designed for a higher residual hardness range and provides stable analysis values directly from the measuring device. It impresses with its consistent responsiveness, even with demanding water quality requirements. Key features and typical applications of the Indicator 320 Measuring parameter: Residual hardness in water Specified limit value: 2 °dH (medium to higher hardness ranges) Package size: 500 ml original indicator solution Compatible with: Testomat 808 and Testomat F-BOB Advantages: larger supply quantity for longer measurement intervals, stable measurement reaction, ideal supplement for automated water analysis
Heyl Testomat 808 Original Indicator 330 Residual hardness threshold measurement with the Testomat 808 The Testomat 808 Indicator 330, 500 ml bottle, is used for measuring residual hardness. Indicator 330 monitors residual hardness at a value of 1.5 °dH and is suitable for use with the Testomat 808 and F-BOB devices. Testomat 808 Indicator 330 – Reliable Residual Hardness Monitoring at 1.5 °dH The Testomat 808 Indicator 330 was specifically developed for monitoring residual hardness in water treatment. With a defined threshold of 1.5 °dH, this indicator solution is ideal for applications with the corresponding water hardness. It is fully compatible with Testomat 808 and Testomat F-BOB devices and ensures stable, continuous measurement in your water treatment processes. The original indicator from Heyl provides a clear and reliable color change, allowing for a quick assessment of water quality. Using the original indicator solution ensures high process reliability and supports uninterrupted operation of your systems. Heyl Original Indicator – Your Safety for Measurement, Device, and Warranty Using the original Testomat 808 Indicator 330 is an essential part of reliable residual hardness monitoring. Only original indicator solutions ensure that the manufacturer’s specified measurement accuracy and functional parameters are consistently maintained. At the same time, using the original indicator ensures: the retention of warranty and guarantee claims proper operation of the measuring devices precise measurement results and long-term investment and operational security Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Liquid indicator solution for measuring residual hardness in water with the Testomat 808 and Testomat F-BOB limit value measuring devices – 2x100ml bottles with a limit value of 3 °dH for the medium to higher hardness range. Indicator 330 – reliable residual hardness monitoring with Testomat 808 Measuring solution for detecting residual hardness up to 3 °dH Indicator 330 for the Testomat 808 limit value measuring device is a specially developed liquid solution for the precise measurement of residual hardness values up to 3 °dH. It provides clear signals directly in the Testomat 808 or F-BOB, enabling deviations in water hardness to be detected at an early stage. The solution's reliable response to the defined limit value enables continuous monitoring of process water, boiler feed water and technical water systems. Clear signals for water analysis with Heyl analysers Measurements can be carried out quickly and reliably with the Indicator 330 directly in the devices. The defined reaction threshold at 3 °dH ensures clear measurement results, making it easy to monitor water quality and process control. Technical details and typical areas of application for indicator 330 Measured parameter: Residual hardness in water Limit value: 3 °dH Package size: 2x100 ml original indicator Compatible analysers: Testomat 808 and Testomat F-BOB Advantages: clear limit value display, easy integration into existing measurement routines, stable reaction signals Areas of application: technical water supply, process water monitoring, reverse osmosis systems
Originale 500 ml-Indikatorlösung zur Messung von Resthärte im Wasser – ausgelegt auf einen Grenzwert von 5 °dH. Kompatibel mit Testomat 808 und F-BOB. 500 ml indicator solution 350 from Heyl – residual hardness monitoring up to 5 °dH Reliable liquid solution for detecting increased residual hardness The Testomat 808 Indicator 350 is specially designed for detecting higher residual hardness values up to 5 °dH. With its measuring range, it helps to reliably detect changes in water quality even in more robust hardness ranges, especially where medium to significant residual hardness is present. Powerful for more pronounced hardness The indicator is particularly suitable for water analysis in applications where the residual hardness is not only low but also significantly pronounced. Thanks to its robust calibration, it delivers reproducible results even under more demanding process conditions. Key features and typical applications of indicator 350 Measured variable: Residual hardness in water – important indicator of water quality and process stability Limit value: 5°dH – for medium to high hardness levels Contents: 500 ml original indicator solution Compatibility: Suitable for Testomat® 808 and Testomat® F BOB measuring systems Advantages: larger liquid quantity for longer intervals between refills, stable analysis response, easy integration into automated measuring processes Areas of application: Monitoring of water in reverse osmosis systems, supply systems, boiler feed water and technical water processes
Original Heyl Testomat 808 SiO₂ Reagent A – Reliable Silicate Measurement First reagent for Testomat 808 SiO₂ measurement The Testomat 808 SiO₂ Reagent A is used to measure the silicate content in water (SiO₂) and is one of the two necessary reagents for silicate measurement with the Testomat 808 Silicate system. SiO₂ Reagent A initiates photometric silicate determination in the Testomat® 808 SiO₂. The measurement range is 0.3–1.2 ppm SiO₂. Reagent A is precisely calibrated to the measurement method of the Testomat 808 Silicate and allows reliable silicate measurement in the range of 0.3 to 1.2 ppm SiO₂. It is ideal for use in RO process water treatment, e.g., in clinical environments. Using the original reagent ensures consistently precise results, which are essential for stable process monitoring. Heyl Original Indicator for Silicate Monitoring in RO Process Water Treatment Using original Heyl reagents ensures not only high measurement accuracy but also proper operation of the Testomat 808 SiO₂ and the retention of warranty and guarantee claims. It is ideal for clinical applications where reliable silicate monitoring is critical. For example, in sterilization of medical instruments, silicate monitoring in RO process water plays a key role in protecting and preserving medical devices. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Original Heyl Testomat 808 SiO₂ Reagent B for Silicate Determination Second reagent for silicate measurement with the Testomat 808 Silicate system The Testomat 808 SiO₂ Reagent B is the second required reagent for photometric measurement of silicate content (SiO₂) in water. SiO₂ Reagent B, together with Reagent A, completes the silicate determination using the Testomat® 808 SiO₂. The measurement range is 0.3–1.2 ppm SiO₂, enabling reliable and reproducible silicate analysis. Reagent B is precisely calibrated to the Testomat 808 Silicate measurement method and allows reliable determination of silicate within the 0.3–1.2 ppm SiO₂ range. Advantages of Using Original Reagent B for Testomat 808 SiO₂ by Heyl Using original Heyl reagents is essential for the proper operation of the Testomat 808 SiO₂ measuring device. It significantly contributes to process reliability, long device lifespan, and the retention of warranty and guarantee claims. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Original reagent kit from Heyl for measuring silicate in water for use in the Testomat 808 SIO2 – two 100 ml bottles (A+B) for precise SIO2 monitoring. SIO2 reagent kit for Testomat 808 – reagents A+B for silicate measurement Complete A+B reagent set for reliable determination of silicate content The Testomat 808 SIO2 reagent set A+B consists of two original 100 ml bottles of reagents A and B, which have been specially developed for photometric silicate measurement. The kit covers the entire measurement process and is ready for immediate use. Thanks to the coordinated measurement range of 0.3 to 1.2 ppm SIO2, even low silicate concentrations can be reliably detected. Advantages of the original reagent kit for silicate measurement from Heyl With the A+B reagent set, you can use precisely coordinated components for silicate determination in the Testomat 808 SIO2. The reagents are factory calibrated and guarantee consistently reproducible results in the monitoring range from 0.3 to 1.2 ppm SIO2. Application & areas of use Measuring parameter: Silicon dioxide in water – particularly important for pure or deionised water. Measuring range: approx. 0.3–1.2 ppm SIO2 – tailored to the capacity of the Testomat 808 SIO2 system. Package contents: 100 ml each of reagent A and reagent B Areas of application: Monitoring of silicate in deionised water, process water, in clinical sterilisation processes or other technical water systems. Advantages: Original reagents ensure continuously accurate measurements and support the functional integrity of the measuring system.
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing Safety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General information Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °C From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808! Optional accessories: NeoTecMaster unit hood
Precise Water Hardness Analysis for Automated Process and System Monitoring with the Testomat EVO TH Fully automatic water hardness determination via titration The Testomat EVO automatically detects the water level when filling the measuring chamber and can also operate for extended periods in BOB mode without constant supervision. With an integrated SD card or optionally an SDHC card (2 GB), measurement data and messages/alarms can be recorded. The menu is available in multiple languages, and firmware updates can be conveniently applied via the SD card. Analog outputs and serial interfaces allow external processing of measurement data. Certified and Cost-Effective Standalone Water Hardness Meter With the Testomat EVO, you benefit from stable, low-maintenance continuous operation, minimal consumption of indicator solution and water, as well as versatile data communication via RS232 or 0/4–20 mA signals. Certification according to relevant safety and TÜV standards (WÜH certification for boiler houses) and the compact design make the EVO a robust and efficient solution for demanding measurement tasks. Applications for the Testomat EVO Water treatment Drinking water systems Industrial boilers Process water monitoring When purchasing the Testomat EVO online, you receive, in addition to a 3 % online discount on Heyl devices, a free indicator of your choice. Frequently asked questions How long is the warranty period for the Testomat EVO TH? The warranty period for the Testomat EVO TH series is 2 years from delivery. Where can I view or download the operating instructions? The operating instructions can be viewed or downloaded in the online shop, either directly with the item or in a separate download area. How can the values be read out on the Testomat EVO TH? This is possible with the integrated SD card. More detailed information on data readout can be found in the operating instructions. Can the warranty on my Testomat device be extended? A warranty extension on a newly purchased Testomat device is generally possible from 24 to 36 months. The warranty period can thus be extended by one year. The prerequisite for this is that the extension is made within the first three months after the date of purchase. You can access the device warranty extension directly via your online shop customer account. Does the Testomat EVO TH have different spare parts and service sets than the Testomat ECO? No, the spare parts for the Testomat EVO TH and the Testomat ECO are identical. A selection of spare parts for the specific device can also be found in the respective device operating instructions. How high are the follow-up costs for chemicals? Chemical consumption depends on the number of analyses performed with the Testomat EVO TH. Consumption can be determined using our indicator consumption calculator in the online shop. How often does the device need to be serviced? The manufacturer recommends servicing the device once or twice a year. The maintenance interval for the Testomat EVO TH is therefore 6-12 months. Can the device be serviced by a service partner? Yes, maintenance can be carried out by an authorised Heyl Neomeris service partner. Please feel free to contact us if required via vertrieb@heylneomeris.de , so that we can find the right technician for your region. Can the device be sent in for repair (cost estimate)? Yes, the defective device can be sent to our address. A description of the fault should be included with the return shipment and the indicator must be removed from the device before returning it. Once we have received the defective device, you will first receive a cost estimate for the expected repair costs. The repair will only be carried out after prior approval.
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified. It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® functionalities of both devices: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® EVO TH: High-precision titration by means of piston metering pump LCD graphic display Multilingual menu with easy switching (internal programming is retained) External clear / acknowledge input Free programmable password Range monitoring (fall below limit value1 / exceed limit value 2) Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure) Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 100 and 500 ml bottles Analysis trigger: automatic interval operation (0-99 minutes) depending on quantity via contact water meter Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover
Testomat® Indicator TH2005 from Heyl – Precise Low-Range Residual Hardness Measurement 2x100 ml Residual hardness 0.05–0.50 °dH for Testomat 2000 2x100 ml Testomat Indicator TH2005, 2x100 ml bottles, for measuring residual hardness. The original bottles allow direct use without transferring the solution. The Testomat® Indicator TH2005 is an original indicator solution for reliable measurement and threshold monitoring of residual hardness in the range of 0.05 to 0.50 °dH. Supplied in two practical 100-ml original bottles, the indicator enables direct application without transferring. The indicator is particularly suitable for applications with high water quality requirements, where precise monitoring of low hardness ranges is essential. Which devices is the TH2005 indicator from Heyl compatible with? The TH2005 indicator is compatible with the following measuring devices: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat® Limit Which values does the original TH2005 indicator from Heyl measure? The Testomat® Indicator TH2005 covers multiple units and offers high resolution: 0.05–0.50 °dH (Resolution 0.01) 0.09–0.89 °f (Resolution 0.02) 0.89–8.93 ppm CaCO₃ (Resolution 0.2) 0.01–0.09 mmol/l (Resolution 0.01) Using the original indicator ensures high measurement accuracy, proper device operation, and retention of warranty and guarantee claims. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.