Skip to main content Skip to search Skip to main navigation

Testomat® EVO (Successor to the Testomat® ECO)

Product number: 100704
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat® EVO (Successor to the Testomat® ECO)"

Precise Water Hardness Analysis for Automated Process and System Monitoring with the Testomat EVO TH

Fully automatic water hardness determination via titration

The Testomat EVO automatically detects the water level when filling the measuring chamber and can also operate for extended periods in BOB mode without constant supervision. With an integrated SD card or optionally an SDHC card (2 GB), measurement data and messages/alarms can be recorded. The menu is available in multiple languages, and firmware updates can be conveniently applied via the SD card. Analog outputs and serial interfaces allow external processing of measurement data.

Certified and Cost-Effective Standalone Water Hardness Meter

With the Testomat EVO, you benefit from stable, low-maintenance continuous operation, minimal consumption of indicator solution and water, as well as versatile data communication via RS232 or 0/4–20 mA signals. Certification according to relevant safety and TÜV standards (WÜH certification for boiler houses) and the compact design make the EVO a robust and efficient solution for demanding measurement tasks.

Applications for the Testomat EVO

  • Water treatment
  • Drinking water systems
  • Industrial boilers
  • Process water monitoring

When purchasing the Testomat EVO online, you receive, in addition to a 3 % online discount on Heyl devices, a free indicator of your choice.

Dimensions

Height 48 cm
Length 28 cm
Width 38 cm

Weight

Weight 9,1 kg

Other attributes

Country of origin EU
Customs tariff number 90278990
Technical specifications
Supply voltage: switching power supply 100-240 VAC, 100-353 VDC
Power consumption: max. 30 VA
Protection class: I
Protection: IP 44
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa (after removal of the valve body)
Weight: approx. 9,0 kg
Menu Language: German, English, French, Dutch, Spanish, Turkish, Chinese, Czech, Russian (others on request)
Measuring range: Water hardness: 0.89 - 448 ppm

Tender Text

Tender documents available for download as Word (*.docx) or PDF (*.pdf) files DE/EN

Tender text Testomat EVO TH

Performance description:

automatic water hardness analyzer for continuous online monitoring of residual total hardness in water treatment plants.

Type:

Microprocessor-controlled limit value measuring device that automatically checks water hardness using an indicator pump system

Manufacturer: Gebrüder Heyl Analysentechnik GmbH & Co. KG, Hildesheim

Product name: Testomat® EVO-TH

Article number:

Power consumption

Article number:

24V/50 – 60 Hz

100706

100 – 240 VAC/ 100 – 353 VDC

100704

 

Measuring principle & measuring range:
Titration method using color change with piston dosing pump for precise analysis of total hardness in the range of 0.05–25 °dH (or 0.89–448 ppm), depending on the indicator used.

Fields of Application:

  • Monitoring of water softening systems
  • Water treatment plants
  • Drinking water treatment
  • Industrial boilers
  • General process water monitoring

Technical specifications:

  • Automatic sampling and venting of the dosing pump
  • Optical water detection for level monitoring and evaluation of sample water quality
  • LCD graphic display with multilingual menu navigation
  • Menu navigation with password protection
  • Limit value monitoring with programmable switching logic (under/over)
  • Freely selectable measurement interval times (cyclical or quantity-dependent)
  • External analysis trigger
  • Self-test and error diagnosis functions
  • RS-232 interface and analog output 0/4–20 mA
  • Storage of all system data and logs (measurement values and error messages) on SD card
  • Display units: °dH, °f, ppm CaCO₃, mmol/l
  • Internal memory with data export/import function (SD card)
  • Robust housing: IP44 / protection class I
  • Supply voltage: 100–240 VAC or 100–353 VDC
  • Dimensions: approx. 380 × 480 × 280 mm, weight: approx. 9 kg
  • Permissible ambient temperature: 10–40 °C
  • Permissible water temperature: 10–40 °C
  • Operating pressure: 1–8 bar (or 0.3–1 bar after removing the controller core)

Scope of delivery:

  • 1× Testomat EVO TH with factory calibration
  • 1× SD card (2 GB) for storing measured values, logs, and firmware updates
  • 1× Complete operating and installation manual (English)
  • 1× factory test report / calibration certificate

Optional accessories and operating materials

  • Externally mountable power switch (IP65)
  • Connection set for sample inlet/outlet consisting of PE hose 6/4x1 for water inlet, 2 m drain hose di = 12 mm, 1 ball valve, 1 reducer connector 10 to 6 mm, and reducer nipple 3/8"-1/2
  • indicator for initial commissioning (TH2005, TH2025; TH2050; TH2100 or TH2250; in 500 ml or 100 ml)

Certificates and approvals:

  • Component designation WÜH 21-025
  • UL certified

 

Special notes:

  • Device is factory calibrated and ready for immediate use
  • Connection via external power switch in accordance with DIN EN 61010-1
  • Low consumption of water and indicator solution
  • Suitable for continuous industrial use
  • Calibratable version: Testomat EVO TH CAL available
Skip product gallery

We recommend our indicators, as well as the following accessories

Testomat® Indicator TH2005 500ml, bottle with product label and measuring range 0.05–0.50 °dH, water quality test
Testomat® indicator TH 2005, 500ml
Product number: 152005

Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Where can the TH2005 indicator be used? It is suitable for water treatment, industry, and supply technology. Compatible with the following devices: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomat EVO TH Testomat Limit Which measurement ranges does the TH2005 indicator cover? 0.05–0.50 °dH with 0.01 resolution 0.09–0.89 °f 0.89–8.93 ppm CaCO₃ 0.01–0.09 mmol/l

€104.20*
Testomat Indicator TH2025 500ml Front view with white label, 500 ml bottle for measuring residual hardness in water
Testomat® indicator TH 2025 500ml
Product number: 152025

Testomat Indicator TH2025 – for Determining Residual Hardness Precise Residual Hardness Measurement with the TH 2025 for Testomat 2000 and Testomat Limit The Testomat Indicator TH2025 from Heyl is a chemical reagent solution for precise determination of residual hardness. It measures in various units (°dH, °f, ppm CaCO₃, and mmoI/I). Enjoy a 3% discount on Heyl products when ordering online in our HeylNeomeris Shop. With the TH2025 indicator, you can determine residual hardness in the range of 0.25 to 2.50 °dH. The 500 ml bottle provides a convenient dosing solution that can be used directly in the measuring device without any complex preparation. Where can the TH2025 Indicator be used? The indicator is suitable for: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomar EVO TH Testomat Limit What are the measurement ranges? 0.25–2.50 °dH, with a resolution of 0.05 0.45–4.48 °f, with a resolution of 0.10 4.48–44.8 ppm CaCO₃, with a resolution of 0.9 0.04–0.45 mmoI/I, with a resolution of 0.01

€104.20*
Testomat® Indicator TH2050 500 ml for testing water hardness
Testomat® indicator TH2050 500ml
Product number: 152050

The 500 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5 - 5.0 °dH only for Testomat® EVO TH and Testomat® LAB TH.

€107.70*
500ml bottle of Testomat® TH2100 with product label
Testomat® indicator TH 2100 500ml
Product number: 152100

Testomat Indicator TH2100 for Determining Elevated Residual Hardness Indicator solution for precise monitoring of residual hardness in the higher limit range 1.00–10.00 °dH The Testomat Indicator TH2100 from Heyl, 500 ml bottle, is an original indicator solution for determining residual hardness in the higher hardness range of 1.00–10.00 °dH in water treatment systems. The bottles are designed for use in Testomat devices and enable continuous and reliable monitoring. The TH2100 indicator is specifically designed for higher residual hardness levels. It supports safe process control in industrial and commercial water treatment systems. What measurement ranges does the TH2100 indicator cover? 1.00–10.00 °dH, resolution 0.20 1.79–17.9 °f, resolution 0.40 17.9–179 ppm CaCO₃, resolution 3.8 0.18–1.79 mmoI/I, resolution 0.04 Which Heyl Testomat devices is the indicator suitable for? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit

€107.70*
Testomat® indicator TH2250 500 ml bottle for measuring water hardness, clearly legible label
Testomat® indicator TH 2250 500ml
Product number: 152250

Original Indicator Testomat Indicator TH2250 in the 500 ml Bottle from Heyl Precise Residual Hardness Measurement for Testomats The Testomat Indicator TH2250, 500 ml bottle, measures residual hardness in water samples and is suitable for use in our measuring devices Testomat 2000, Testomat EVO, and the new limit measuring device Testomat Limit. The measuring range is 2.50–25.00 °dH with a resolution of 0.50. Thanks to precise measurements, it supports compliance with quality standards in industrial water treatment. It is designed for long service life, minimizing maintenance and downtime. The TH2250 indicator allows reliable, automatic determination of residual hardness in water. What limit values can be measured with the TH2250? 2.50–25.00 °dH, resolution 0.50 4.48–44.8 °f, resolution 0.40 44.8–448 ppm CaCO₃, resolution 3.8 0.45–4.48 mmoI/I, resolution 0.04 Where can the indicator be used? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit