Those who opt for consulting have knowledge and can therefore clearly recognise when it is time to call in competent help. We have been specialising in the treatment of process water for decades. One of our focal points here is the ingredients of water and their effects. We deal with well water, drinking water and tap water as well as the production of ultrapure water. Originally, Gebr. Heyl Vertriebsgesellschaft came from the field of measuring, control and regulation technology (MSR) components for all process water issues. We have therefore long been involved in both disinfection technology (ozone, UV, chlorine dioxide) and system technology - systems that ensure water quality. It is hardly surprising that we have now acquired solid practical experience in addition to profound theoretical knowledge.
We have also specialised in process water treatment in hospitals and have extensive expertise in this area. With this know-how as a basis, we can offer what is necessary for you to achieve the desired result of your measures. Together with your expertise in your sector, we want to ensure that you take the safest route on the "water side".
Our range of services can be described quite simply:
We ...
... analyse,
... evaluate,
... document,
... argue (also economically),
... develop effective solutions,
... make recommendations for action,
... accompany your tender,
... check the technical accuracy of offers,
... conduct and accompany the technical discussions.
And last but not least: we validate your process!
Filter products
Reliable and economical demineralized water treatment (demineralized water) is indispensable in sterile processing. However, processes, system status and operating costs are subject to constant change. As part of our basic on-site analysis, you will receive a well-founded and independent assessment of your existing demineralized water treatment system - directly at your location. Our consulting approach aims to identify optimization potential at an early stage and make it economically viable. Among other things, we look at Plant technology and dimensioning Equipment and feed technology Instruments used In sensitive environments such as hospitals, the quality of the demineralized water used is crucial - especially in areas such as sterile goods processing, laboratory diagnostics or medical technology. On request, we can also carry out targeted and professional water sampling at representative sampling points for a fee. Some of the water samples taken are analyzed on site using photometric measurements and then sent to an accredited laboratory. The results are documented in a clearly structured report - including an assessment and specific recommendations for optimization.
Focus on efficiency, quality and safety The supply of demineralized water (demineralized water) is of central importance in many areas of a clinic - for example in central sterilization, laboratory analysis or medical technology. At the same time, the requirements for efficiency, operational safety and hygiene are constantly increasing. Our on-site process analysis provides you with a structured evaluation of the existing demineralized water treatment - with a focus on efficiency, supply reliability and compliant implementation. Our consulting approach includes, among other things System survey and weak point analysis Recording the entire process chain - from the raw water supply to softening, desalination, filtration, storage and distribution systems. Comparison with the actual water demand Checking whether system capacities, retention times and storage volumes match the current and future usage situation. Evaluation of technical and organizational interfaces z. e.g. transfer points to medical technology, automatic rinsing cycles, instrument logistics, redundancy concepts, etc. Risk analysis with regard to microbiological and technical weak points incl. recommendations for sampling, avoidance of downtime contamination and material safety. Economic efficiency analysis Consideration of e.g. use of chemicals, personnel costs and optimization possibilities. As part of our process analysis, we work with you to determine The relevant withdrawal points in the supply system (e.g. after the demineralization plant, at points of consumption, in the return area) The correct sampling technique Possible influences on the measurement results (e.g. dead volume, stagnation, material compatibility) Requirements for microbiological and chemical-physical analysis Adapted to the medical requirements of the facility The aim of sampling is to obtain a realistic picture of the water quality in the facility and to identify potential risks at an early stage. Our independent analysis supports you in complying with regulatory requirements, strengthening internal quality assurance measures and ensuring the long-term operational safety of your demineralized water treatment. The results are documented in a clearly structured report - including an assessment and specific recommendations for optimization. Our process analysis creates transparency, identifies optimization potential and forms the basis for well-founded investment decisions or quality assurance measures. You receive clear documentation with specific recommendations for action - practical, independent and tailored to your clinic.
The reliable supply of demineralized water (demineralized water) to the AEMP is a critical factor for the flawless reprocessing of medical devices. Decision-makers in hospitals are faced with key questions: What are the requirements for water quality? Which pipe materials are suitable? How can a standard-compliant, hygienic and economical solution be planned and implemented? We support you in all project phases - from technical planning to material selection and implementation - with the following focal points: Determination of demand & load profiles: Analysis of peak consumption (e.g. washer-disinfectors, autoclaves), design of water treatment and storage solutions according to AEMP capacity. We take into account not only current but also future requirements. Requirements of current DGSV and AKI guidelines: Ensuring compliance with the required limit values for conductivity and silicates. Line design & material selection Technology concept: selection of suitable DI system technology Economic efficiency analysis: focus on life cycle costs, energy efficiency and maintenance costs. Our manufacturer-independent advice ensures that your investment functions reliably, compliantly and efficiently in the long term - in the interests of patient, operator and process safety.
The regular validation of the entire reprocessing process and its repeated implementation in the event of interventions or changes within the reprocessing process is an essential instrument for demonstrating process reliability. In the course of our work as technical experts, we verify the overall process, assist you with sustainable documentation, continuously monitor the effectiveness of the measures introduced, coordinate the involvement of all process participants and make recommendations for the involvement of authorised external accredited bodies and specialist companies.